Optical Spot Spraying Compliance: Nozzles, Rates and Staying Legal After the Permit Ends
Optical spot spraying (Weed-IT, WeedSeeker, See & Spray, Carbon Bee, Bilberry and the autonomous platforms built around them) has moved from a useful option to everyday practice on broadacre farms. The chemical savings are real, but compliance is no longer optional or covered by a temporary permit for much of the chemistry you run.
This page pulls together the practical points that actually determine whether your setup is label-compliant once the spray hits the weed: the rate in the target zone, the nozzle that delivers it, and the duty cycle that keeps the pattern intact.
What changes on 31 December 2026
APVMA permit PER90223 currently covers a range of herbicides for use with optical spot spray technology in fallow. That permit ends on 31 December 2026.
Nine Nufarm products already carry optical spot-sprayer rates on their labels (including Amicide Advance 700, Amitrole T and Comet 400). For everything else, growers will need either a full label rate written for optical use or to fall back to standard boom rates. The nine that moved to full registration are the clearest path; the rest require checking the current label before the season starts.
All registered products can still be used at their normal per-hectare boom rate through an optical sprayer if no optical rate is specified. The higher “spot” rates only apply where the label or (until 31 December) the permit explicitly allows them.
Target zone rate is the rate that matters
The official position, confirmed in correspondence with Gary Dorr of the APVMA, is that the optical rate is intended for the target zone — the area the nozzle is actually treating when it fires.
Calibrating so that a single nozzle delivers the equivalent of 100 L/ha across its full measured spray width often puts substantially more than the intended rate onto the weed itself. The preferred approach is to size the tapered fan nozzle so the target zone receives the label optical rate, accepting that the edges of the pattern will be lower. When adjacent nozzles also trigger, the overlap restores coverage.
This is why measured distribution in the target zone, not just fan angle or catalogue spray quality, determines compliance. The full Q&A is here: The OFFICIAL green light for single spot Target Zoning.
Nozzle requirements for PWM optical systems
Most current optical and autonomous systems use pulse-width modulation. That imposes practical limits:
Duty cycles should stay high enough (ideally above ~75 % at normal operating speed) so there is headroom for turning and speed changes without dropping into the range where pattern quality collapses.
Air-induction nozzles generally lose pattern integrity below 30–40 % duty cycle because the venturi cannot sustain atomisation on short pulses. Non-air-induction hydraulic nozzles (such as the ARAG CFLD range) maintain a usable pattern further down the duty-cycle range.
110° nozzles on typical 50 cm spacing create excessive overlap and edge under-dosing in single-spot work. Narrower angles (80° and below) paired with correct height give cleaner target-zone coverage. See the article “All 110° nozzles on spot sprayers – Bad!” for the measured reasons.
Spray quality on the label (especially for 2,4-D) must still be met inside the target zone at the pressure and duty cycle you actually run.
SpraySpotter is built around these constraints. It calculates target-zone rate, duty cycle headroom and nozzle size for the common optical platforms rather than treating them as ordinary boom nozzles.
Common failure points
Running the same nozzle size that was correct under the permit once the label rate changes.
Using air-induction nozzles at the low duty cycles common in single-spot or side-safety modes.
Not setting the controller to a full-boom rate while the nozzles are sized for a single-spot target zone (or the reverse).
Ignoring the difference between spray-width rate, target-zone rate and overlapping rate. The three rates are not interchangeable; the label cares about the one that lands on the weed.
Next steps
Check whether your chemical inventory is one of the nine Nufarm products with optical rates already on the label, or whether it will lose permit coverage on 1 January 2027.
Measure or confirm your actual target-zone distribution rather than relying only on catalogue charts.
Run the job through SpraySpotter with your speed, pressure, nozzle spacing and desired optical rate.
Select a PWM-compatible non-air-induction nozzle (CFLD-C, CFLD-XC) that keeps duty cycle high and meets the required rate in the target zone.
The ARAG ASJ CFLD range stocked at Fantastic Nozzles is purpose-built for exactly this combination of PWM, optical duty cycles and Australian label spray-quality requirements. Call Dave on 1800 920 312 if you want the numbers checked against a specific machine or product.
Regards,
Dave Young
0422 131 123
Related reading: